Dry Chemical System and Open-Face Spray Design, Installation, Operation, and Maintenance Manual

Dry Chemical System and Open-Face Spray Design, Installation, Operation, and Maintenance Manual

The Kidde Dry Chemical System and Open-Face Spray Design, Installation, Operation, and Maintenance Manual provides fire protection for a variety of special hazard applications.  The IND system holds UL listings and FM Approvals as a pre-engineered system.Systems shall be designed and implemented according to the following:

  • NFPA Standard 17, “Standard for Dry Chemical Systems”,
  • NFPA Standard 33, “Standard for Spray Applications Using Flammable or Combustible Material”,
  • Other applicable NFPA standards as required for a particular application and design, including, but not limited to, NFPA 70
  • (NEC) and NFPA 72, Fire Alarm Standard.
  • This Design, Installation, Operation, and Maintenance Manual.
  • Any other standards enforced by a local Authority Having Jurisdiction (AHJ).

Configurations in Chapter 3, System Design, tested and listed to Underwriters Laboratories (UL) Standard 1254, and FM Approved. Open-Face Spray Booth configurations (Section 3-2.3)  tested and listed to UL Standard 1254.

Dry Chemical System and Open-Face Spray Design, Installation, Operation, and Maintenance ManualDry Chemical System

  • GENERAL INFORMATION
  • COMPONENT DESCRIPTION
  • SYSTEM DESIGN
  • INSTALLATION
  • MAINTENANCE
  • PARTS LIST
  • APPENDIX A ELECTRICAL DETECTION INSTALLATION (DETECT-A-FIRE®)

GENERAL CHARACTERISTICS OF THE KIDDE IND SYSTEM

The Kidde IND System is a dry chemical fire suppression system with two types of agent. The system is capable of encompassing a wide variety of application requirements.The system utilizes stored pressure agent cylinders. Stored pressure cylinders:

  • Remain free of contamination
  • Reduce the packing of the agent
  • Provide a smooth flow throughout the discharge

The cylinders are powder-coated, welded mild-steel shell conforming to DOT 4BW or 4BA construction. The valve  forged brass with chrome-nickel plating. The plating and cylinder coating help to make the assemblies corrosion resistant.The system activated mechanically from manual release, thermo-bulb links, and fusible links.

The Kidde IND Dry Chemical System  a fixed dry chemical system consisting of a supply of dry chemical stored in one or more Cylinder and Valve Assembly. Each cylinder is pressure activated by a System Valve Actuator.The system can be actuated either automatically and/or manually, using mechanical, electrical, or pressure actuation devices. Upon actuation, the dry chemical discharged through agent distribution piping and specially designed nozzles positioned throughout the protected area.