Aerosol Fire Suppression System Design, Operation & Maintenance Manual

Aerosol Fire Suppression System Design, Operation & Maintenance Manual

This Aerosol Fire Suppression System Design, Operation & Maintenance Manual is intended for use with Pyrogen Industrial Fire Suppression Systems. The systems are designed as fixed systems for occupied (requires approval from local authority having jurisdiction), un occupied and normally unoccupied areas.

Those who design, operate, own and maintain these systems should read the entire Manual. Specific sections would be of particular interest depending on one’s responsibility. If there should be any questions regarding this manual, please contact our representatives from a Pyrogen office below or contact the nearest Pyrogen Authorised Representative.

Where required persons who install and commission Pyrogen systems must be approved by the Appropriate Authorities. System Design Approval Certificates must be completed and sent to a Pyrogen office for endorsement prior to supply and installation of a Pyrogen Fire Suppression System. Approved companies may also be required to supply details to the Approval Authority prior to each installation and provide a Commissioning Certificate upon completion of the installation in the specified risk areas.

You can also Read Foam Systems Engineering Manual-Kidde Fire Fighting

Aerosol Fire Suppression System Design, Operation & Maintenance Manual

  • TABLE OF CONTENTS
  • DOCUMENT REVISION CONTROL SCHEDULEAerosol Fire Suppression System
  • FOREWORD
  • SECTION 1. GENERAL

1.1 Terminology
1.2 Pyrogen Product Standards/Testing
1.3 What is Pyrogen?
1.4 Pyrogen Chemical Identity
1.5 Pyrogen Generator Construction
1.6 Pyrogen Extinguishing Action
1.7 Pyrogen Applications
1.9 Pyrogen Safety Data
1.10 Pyrogen Environmental Characteristics
1.11 Pyrogen Technical Characteristics

  • SECTION 2. SYSTEM DESIGN FOR TOTAL FLOODING APPLICATIONS

2.1 General
2.2 Design Methodology
2.3 Design application density
2.4 Design Quantity
2.5 Number of EXA generators
2.6 Pyrogen Range
2.7 Minimum Holding Time
2.8 Enclosure Requirements
2.9 Design Limitations
2.10 Pyrogen Discharge

  • SECTION 3. SYSTEM DESIGN FOR LOCAL APPLICATIONS

3.1 PYROGEN PACKAGED SYSTEMS.

  • SECTION 4. SYSTEM OPERATION

4.1 Electrical automatic operation
4.2 Electrical manual operation
4.3 Thermal automatic operation
4.4 System isolate switch
4.5 Operating devices
4.6 Detection, alarm and control systems, indicating equipment, warning devices
4.7 Post-fire procedure

  • SECTION 5. SYSTEM COMPONENTS
  • SECTION 6. SYSTEM INSTALLATION

6.1 Prior to installation
6.2 Spacing and Location
6.3 Mounting Methods
6.4 Electric Wiring

  • SECTION 7. SYSTEM MARKINGS

7.2 Pyrogen Installation and Expiry Date Label
7.3 Pyrogen Warning & Instruction Signs

  • SECTION 8. SYSTEM COMMISSIONING
  • SECTION 9. SYSTEM MAINTENANCE
  • SECTION 10. SAFETY MEASURES

10.1 Personnel safety
10.2 Potential hazards
10.3 Re-entry
10.4 Clean- up
10.5 Hot Work
10.6 Storage and Transportation

  • APPENDIX A — APPROVAL DOCUMENTATION

FORM 1 — SYSTEM DESIGN APPROVAL CERTIFICATE
FORM 2 — COMMISSIONING AND ACCEPTANCE TESTING
The FORM 3 — NOTICE OF COMPLETION
FORM 4 — MAINTENANCE CHECK LIST
FORM 5 — ANNUAL MAINTENANCE CERTIFICATE

  • APPENDIX B — LIST OF EXA MODULES, SYSTEM COMPONENTS AND SPARE PARTS

 

Download

Aerosol Fire Suppression System Design, Operation & Maintenance Manual

Solved Example Aerosol Fire Suppression System 

Calculation Sheet Aerosol Fire Suppression System 

OR 

Operation & Maintenance Manual

Solved Example

 

Calculation Sheet